HPE ProLiant ML350 Gen9 Server: Access product support documents and manuals, software, download drivers by operating. Learn how to download and install the HPE Smart Update Manager for the HPE Smart Array P440 Controller, a high-performance SAS RAID controller for 12 Gb/s SAS connectivity. corruption. Squeeze: DL980 G7 : SAS Hotplug :Click the link for "Get drivers, software & firmware. Hey all, I have an ESXi 5. 4. How to update the firmware of HPE Smart Array E200i Controller? Watch this video tutorial to learn the steps and tips for a successful firmware update using the HPE Smart Update Manager. Here is the config: Text => ctrl all show config detail Smart Array P400 in Slot 1 Bus Interface: PCI Slot: 1 Serial Number: P61620F9VV6I1I Cache Serial Number: PA2270H9VV538J RAID 6 (ADG) Status: Enabled Controller Status: OK Hardware. Integrated Systems. 04 is not supported. Explore the new digital customer experience engagement platform. The P440ar controller with cut heatsink allows for clearance when a GPU is installed in the secondary full height riser cage. As mentioned earlier, with modern firmware, you can use any disks you want. 00. Firmware - Storage Controller. このガイドでは、HP Smartアレイコントローラーの機能、取り付け、および設定に関する情報について説明します。Troubleshooting Update. If the POST errors are suggesting the battery be replaced, you should absolutely get a new battery. I did not try the b140i which is on the mainboard. may have older product names and model numbers that differ from current models. Product Bulletin, research Hewlett Packard. + HP 881457-B21 Enterprise - Hard drive - 2. In our testing, applying the recommended firmware on servers with this configuration will cause the server to freeze at post. 0Gbps link speeds, even if they're 6G drives. HPE ProLiant DL380p Gen8 Server- Smart Array P420 Controller failure and lockup 0x14. get on the vSAN HCL for vSAN version X and then losing interest, not bothering about later vSAN versions. Users can learn how to create, delete, modify, and move logical drives, as well. rpm 7. To avoid this issue, DO NOT USE the HPE Smart Array or HPE Smart HBA controller firmware verion 4. 32 Physical drives: 12. Online ROM Flash Component for Windows (x64) - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and P841 Release Version and/or Date: 7. SAAP is a collection of additional and advanced controller features embedded in the firmware of select Smart Array controllers. . Model : HP Smart Array P440ar controller: Device Type : SAS: DID : 3239: Brand Name : HP: SVID : 103c: Number of Ports: 8: SSID : 21c0: VID : 103c: Notes: Firmware. For this reason, when first upgrading firmware on an embedded controller from an older version to version 4. - p440ar make the fans sound like a rocket. Install the host using HP's custom ESXi 6. This reduces the risk of flashing firmware to the controller. If the running firmware version is previous to GL210xxxx, the Smart Component will block the upgrade with a message. Mar 30, 2022. Hmmm. 74-1OEM. 5. This release of Gen9 Service Pack for ProLiant (SPP) including support for Gen9 Blade systems is a comprehensive systems software and firmware update solution, which is delivered as a single ISO image. Share Sort by: Best. 0. 0. Then it doesn't matter whether I use the onboard SATA or use the P440ar (in HBA mode). Linux. The National Institute of Standards and Technology (NIST) issued the FIPS 140–2 requirements and standards for cryptography modules that include both hardware and software components. HPE ProLiant Gen9 Server - HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter: Resetting to Factory Defaults. HPE Smart Array P440ar Controller. HPE ProLiant DL/ML/BL Server - How to Upgrade/Downgrade Controller Firmware from BIOS. 52, Hardware. Problematic firmwares include 2. Thanks. The HPE Smart Array P440ar Controller is a Flexible Smart Array, 12 Gb/s SAS RAID controller that provides enterprise-class storage performance, increased internal scalability with SAS Expander Card, and data protection for HP ProLiant Gen9 rack and tower servers. Offers integrated 2 GB DDR3-1866 Flash Backed Write Cache providing up. Intelligent Provisioning provides installation help for Microsoft Windows, Red Hat and SUSE Linux, and VMware operating systems. You are viewing the most relevant and current results for this product. exe) - Operating System : Windows Server 2012 R2 - SmartArray Driver : HPE ProLiant SmartArray HPCISSS3 controller driver version 106. 65-0 in the VMware Compatibility Guide): Printer Setup, Software & Drivers; Printing Errors or Lights & Stuck Print Jobs; DesignJet, Large Format Printers & Digital Press; Sprocket; Samsung; Printers Knowledge Base; Printer Wireless, Networking & Internet; Printer Ink Cartridges & Print Quality; Printer Paper Jams & Feed Issues; Desktops Desktop Software and How To Questions Re: How do I download firmware . BenefitsUpdate the server firmware ("Methods for updating the firmware" on page 12). Version History: Product Bulletin, research Hewlett Packard Enterprise servers, storage, networking, enterprise solutions and software. It was working fine, then I have updated the HP Smart Array P440ar firmware, rebooted the host (twice), and the same command which was working before. The HPE Secure Encryption, a data encryption solution with a smart array controller designed for HP Gen 9 servers, protects mission-critical and sensitive data. 4 TB - hot-swap - 2. 00 Firmware Dependency:. The iLO firmware version has already been displayed, so the firmware module related to the initialization of the iLO functionality is probably already successfully executed. The HPE Smart Storage Administrator (HPE SSA) is a web-based application that helps you configure, manage, diagnose, and monitor HPE ProLiant Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs), HPE Storage controllers, and future devices such as SCSI Express drives, and SAS. 550. AlphaVPS - Alex. It looks like a sinus wave. Troubleshooting Update. Dual 8Gb microSD Enterprise Midline USB device. 03 $ 181. It features eight internal physical links and delivers increased server uptime by. May 13, 2021. Collapse all. • 4LFF drive configuration — Connect the 4LFF. Even for cards where you can manage to get proper SMART support, this really isn't worth the risk. 65 (B) (also denoted as 1. ROFL!!! lol changing it to 2GB file size for benchmark, wow. Troubleshooting Update. Logical drive initialization. HP Software Depot. 2. Prerequisites The iLO IP address or PQDN/FQDN is needed to connect to the iLO web interface. Enable HPE SSD Smart Path to improve Solid State Drive (SSD) read performance by bypassing the Smart Array firmware for the optimal performance path to the SSD. On HPE Gen10/Gen10 Plus platforms with certain HPE Smart Array SR Gen10 controllers, if controller firmware version 2. 00 Firmware Supports Online Firmware Activation: False Rebuild Priority: High Expand Priority:. Firmware - Storage Controller. HPE Smart Storage Administrator (HPE SSA) for Linux. 60(B). It should be quite a good hba, from what I understand both the P440 and H240 use the same controller (same as the mid gen p430/p431), H240 simply lacks the flash backed cache and power loss battery. Showing 1-10 of 529. 04,. Format new array and restore data from tape backup. The disk detection during installation fails to detect the array. HPE Smart Array P440ar Controller cabling. This release of Gen9 Service Pack for ProLiant (SPP) including support for Gen9 Blade systems is a comprehensive systems software and firmware update solution, which is delivered as a single ISO image. Proactive notifications. 5inch SFF 512e Digitally Signed Firmware SAS-12Gbps Smart Carrier. HPE Smart Array P440ar Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. HPE Smart Array P440ar Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. 02 (or later). Firmware/Drivers and Software for Intel® RAID and Storage Products. Option Part Number. HP Proliant DL380 G9 / HPE Smart Array P440ar Controller: not detected intermittently. 5. This x64 Smart Component provides firmware for the following storage controllers: Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and P841. It has P440ar adapter, which works with the "new" hpsa driver. Release Device Driver Firmware Package Version Firmware Version Queue Depth Driver Type vSAN Type Features And points out a problem with HP's software. Download Software. 03. Detected operating system: Choose a different OS . vib for P440ar? This is browser related, when I use firefox it is asking how to handle the file (download, open, etc. Deploys and manages HPE Secure Encryption, a data protection solution. 8TB SAS 12G Enterprise 10 K SFF (2. 0-RELEASE and a RAIDZ2 zroot, FWIW. error: enumInstances No data received from server [root@esxi:~] vmware -vl. 0u3 with HPE image installed on HP Proliant DL360 Gen9. The HPE Smart Array P440ar Controller delivers 12 Gb/s SAS connectivity on HP ProLiant Gen9 Servers when connected to 12 Gb/s internal storage devices for increased performance in messaging, database or general server applications. 88 Firmware Dependency: None Enhancements/New. 5 RHEL. The document also includes installation instructions, configuration guidelines, and troubleshooting tips. 3. Online ROM Flash Component for Windows (x64) - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and P841 Release Version and/or Date: 7. There's 6 of the MM1000GBKAL with firmware HPGE in original trays. for HPE ProLiant DL, ML and Apollo Servers. 52 or newer. Hello guys. Recently I've been trying to build a DL380 Gen 9 according to this playbook, and it isn't working out. But there's no FW for Win2008r2. What does this warning mean, do I have to worry about the health of my raid and virtual machines? Do you advise me to update the controller firmware to the latest firmware version which should be 5. Note: If the controller Management (Mgmt) tool is not available, you are prompted to download. HPE Smart Storage Administrator. Have the same problem with HP DL360 Gen9 server and Smart Array P440ar controller in HBA mode. 5. 3 • SUSE LINUX Enterprise Server 12 SP2 Added Firmware/Software • Added Firmware IT Configuration is the following : - Server ProLiant ML350 Gen9 E5-2620v3 2. Intelligent Provisioning prepares the system for installing "off-the-shelf" and Hewlett Packard Enterprise branded versions of operating system software and integrates optimized ProLiant server support software. for HPE ProLiant DL, ML and Apollo Servers. OS Required: Microsoft Windows Server 2008 R2, Microsoft Windows Server 2008, VMware ESXi 5, Ubuntu 12. ) OP . Online HDD/SSD Flash Component for Linux (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives. I. 5" disks aren't that large in capacity, so you wouldn't be running into issue with that anyway. 24 Serial Number: *snip* Rebuild Priority: Medium. 52) P840 to location 1. Server mode; Smart Update ManagerThe HP Smart Array P440ar Controller is a Flexible Smart Array, 12 Gb/s SAS RAID controller that provides enterprise-class storage performance, increased internal scalability with SAS Expander Card, and data protection for HP ProLiant Gen9 rack and tower servers. You can use the Array Configuration Utility for several tasks such as configuring. 0 build-5310538. 0. Supplemental Update / Online ROM Flash Component for Linux (x64) - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and P841 Release Version and/or Date: 7. 15(B) 2023-07-06. When the update tool is run it will indicate firmware versions currently installed on the server. 10. 0 and also VMWare 5. 00 : HPE NS204i OS Boot Device - Critical Firmware Update Required to Prevent Potential Data Inconsistency Issues During Volume Rebuild HP ProLiantサーバー用HP Smart アレイコントローラー. Get the latest software, documentation and support from HPE. Support. And 2 Intel DC S3710 with firmware G2010110, also in original trays. ユーザーガイド. The National Institute of Standards and Technology (NIST) issued the FIPS 140–2 requirements and standards for cryptography modules that include both hardware and software components. Learn how to troubleshoot and resolve issues with the HPE Smart Array P840 Controller, a 12 Gb/s SAS RAID controller that supports SSD and HDD drives for ProLiant DL380 Gen9 servers. Any idea what's wrong? I guess HPE will call me in a day or two (like. Description. 52. 0 using HP install ISO in both cases (comes bundled with drivers, etc). Now that’s a little bit. ~ # esxcli hpssacli cmd -q “controller slot=0 modify hbamode=on forced". The HPE OmniStack Firmware update is a comprehensive firmware update solution comprised of two bootable images. 0 GA installation media which includes the scsi-hpsa-5. Open Power ISO software and click on New --> hard disc image (last option) Now add firmware file "HPE_luxor. 0, use one of these options. 32 ROM firmware: 8. ProLiant DL360 Gen9 with HP Smart Array P440ar Controller. 2017-04-21. Support. HP Proliant DL380 G9 + Smart Array P440ar + 2x Samsung SSD 850 EVO 1TB - RAID1 - Hello,. 04 is not supported. Hewlett Packard Enterprise support portal for business, enterprise and IT users. 0. The HPE SimpliVity Support Pack provides a comprehensive firmware update for all HPE SimpliVity Gen9 and Gen10 servers. 88 Previous Version of Firmware: 6. 0. ko driver to be outdated as I need a minimum version from September 2014. 1. from time to time, the smart array freeze and the fans produce an excessif noise. Search the support knowledge base, download drivers and patches, create and manage cases, and learn from expert users in forums. 26. The Current Supported Version is the version currently provided by this HP FUP Release. We were trying to boot off mdadm RAID1 (for redundancy) via UEFI - this isn't a particularly simple, common or well-tested configuration so maybe we did something wrong there, rather than anything. Recovery ROM: This feature protects the user from a firmware image corruption by storing a redundant copy of the firmware image. They all behave similarly. TechNet; Products; IT Resources; Downloads; Training; Support. QuickSpecs HPE Smart Array P440ar Controller Standard Features Page 2 Key Features Storage interface (SAS/SATA) • o 8 physical links across 2 x4 internal port s o 12Gb/s SAS, 6Gb/s SATA technology o Mix-and-match SAS and SATA drives to the same controller o Support for SAS tape drives, SAS tape autoloaders and SAS tape libra ries • 2 GiBytes. Genuine bought from a good vendor. Firmware | SATA Storage Disk. Check Consistency. View Profile View Forum Posts View Forum Threads Visit Homepage. 1331820 driver. 5. of 33. Running firmware: 8. VGA is Radeon, and complains about the firmware missing (no acceleration, reduced 2D performance). 52. 60 releases with things like this. This document provides step-by-step instructions, screenshots, and troubleshooting tips for common issues. 0 with HPE Smart Array p440ar - after Smart Array firmware update - STORAGE LOST. Software Details - Online ROM Flash Component for Windows (x64) - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar,. 52. 1. Both hardware raid card have the latest firmware, so as the SAS expander cards and the rest of the server overall (used the latest iso firmware image available from HP). Online ROM Flash Component for VMware ESXi - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and P841 Release Version and/or Date: 7. 2 SSD Enablement Board option cabling; Software, firmware,. 88 Firmware Dependency: None. HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers. Release Date. ESXi showed me a warning on Smart Array P440ar about the firmware version: 3. 15(B) 2023-07-06. 02, and 4. 60 if not 7. HPE Smart Array P440ar Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. You will also find the release notes. The update fixes a critical issue that may cause data loss or corruption. . This is HP’s official website that will help automatically detect and download the correct drivers free of cost for your HP Computing and Printing products for Windows and Mac operating system. Firmware Version: bc 1. Choose a different product . 5, SuSE Linux Enterprise Server 11 SP3, VMware ESXi 5. 150W PCIe power cable option. 46 ncsi 1. For more pre-installation information, see the HPE ProLiant ML350 Gen9 Server User Guide. Download PDF. Update drivers using any of the following Smart Update Solutions : Download the latest Service. The update fixes several issues and improves the stability and performance of the controller. Learn more at the Official Hewlett Packard Enterprise. Version History: RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. Tech Courier. The HPE SSA is a configuration and management tool for HPE Smart HBA and Smart Array controller options. Hi all, I am trying to setup an hp ML350 with the included p440. P440ar Controller HPE Smart Array P440ar/2GB FBWC 12Gb 2-ports Int SAS Controller 726736-B21 NOTE: HPE Smart Array P440ar/2GB FBWC controller option ki t includes the HPE Smart Storage Battery the backup power source necessary to protect the data on the Flash -backed Write Cache as the P440ar will generally be your default P -series The P440ar is green and ok (firmware 5. " Select the appropriate Operating System. 0 only 6. HPE Smart Array P440ar Controller. of 14. 04. Product Support Software & Drivers Warranty Check Enhanced Support Services Education and Training Product Return and Recycling OEM Solutions Validate Equipment Parts. VMware ESXi 6. HPE ProLiant BL460c Gen9 Server Blade: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. el 20-12-2019 09:40 AM. 0. HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers. Any idea what's wrong? I guess HPE will call me in a day or two (like last time). 52 is included in the Service Pack for ProLiant (SPP) Version 2016. The next piece of firmware to execute might actually be the firmware of the Smart Array P440ar Controller. New comments cannot be posted. 5. The webpage also includes installation instructions and release notes for the firmware update. Quick Specs: Part No: 749796-001, 726738-001. . Release Device Driver Firmware Package Version Firmware Version Queue Depth Driver Type vSAN Type FeaturesAnd points out a problem with HP's software. HPE Technology Service Portfolio. 750450-001. 0. , and then select the flash file. HPE Smart Array P440ar Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. Release Date. Doing these steps did get the server back online. Locked post. Install the host using HP's custom ESXi 6. Hmmm. HPE Smart Array P440 Controller. Version History: RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard. The HPE Smart Array P440ar Controller delivers 12 Gb/s SAS connectivity on HP ProLiant Gen9 Servers when connected to 12 Gb/s internal storage devices for increased performance in messaging, database or general server applications. The HPE SSA is a configuration and management tool for HPE Smart HBA and Smart Array controller options. Smart Array P440ar, SAS to HP 1-8 G2 Tape Autoloader, RAID-1 and 10 :. Option 2 sounded much better. Get support for this product . Showing 1 of 1. HPE Smart Array P440ar Controller cabling; HPE Smart Array P840ar Controller cabling; Universal media bay cabling; 150W PCIe power cable option; M. HPE Smart Array P440ar Controller. Description. Oct 24, 2016. thanks. Doing these steps did get the server back online. I configured the 8 SSDs in Raid10, tried several stip size and disable the smart path, tried with or without physical cache activated, i really have bad performance when using. 05 Service Pack for Proliant G9/G10. 2 SSD Enablement Board option cabling; Software, firmware, and utilities. Whether you're a large enterprise or a smaller business, Hewlett Packard Enterprise data protection and recovery software will cost-effectively protect you against disaster and ensure business continuity. This procedure worked as expected. 0 and Below PSODs or VMs May Fail to Start When Using an Nvidia GPU. Online ROM Flash Component for Windows (x64) - Smart Array and Smart HBA H240ar, H240nr, H240, H241, H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and P841 Release Version and/or Date: 7. My solution to the SSD interoperability issue has been to move to PCIe-based SSDs or leverage the SSD caching features of the. We were hoping to use only the HBA mode of the P440ar Smart Array controller for all disks. To locate the drivers for a server, go to the Hewlett Packard Enterprise Support Center website, and then search for the product name/number. HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers. Chose Embedded RAID 1: Smart Array P440ar controller. HPE Smart Array P420 Controller: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. The iLO firmware version has already been displayed, so the firmware module related to the initialization of the iLO functionality is probably already successfully executed. This can be done with the following command: # License key installation . Download Software. Software running on this is limited to working on CentOS 5. Service Pack for ProLiant. disks will show up in vSphere web client for vSAN. 02 includes an update to the embedded controller’s CPLD image. Software CD, web, or embedded in the system Software CD or Web Preinstalled in ROM of HP Smart Array controllers When the utility can be used All formats can be run in online and offline environments. 101 Software and firmware. Firmware can only be upgraded from the last two major firmware releases. 00) in slot 0 (embedded RAID) and a P840 controller (FW ver 2. 2 SSD Enablement Board option cabling; Software, firmware, and utilities. Welcome to Software and Drivers for . The HPE Smart Array P440ar Controller is a Flexible Smart Array, 12Gb/s SAS RAID controller that provides enterprise-class storage performance, increased internal scalability with SAS Expander Card, and data protection for specific HPE ProLiant Gen9 rack and tower servers. Please power off the hardware, remove power. Choose a different product . HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers. Victor 0 08-08-2016, 08:24 AM #2. It supports various HPE ProLiant Gen9 servers and provides solutions for cache memory failure and other issues. /ssacli ctrl slot=1 licensekey XXXXX-XXXXX-XXXXX-XXXXX-XXXXX # License key removal . of 33. or you should call the local HPE support center to replace the HPE SD-card. The HPE Smart Array P840ar Controller is a flexible Smart Array 12 Gb/s Serial Attached SCSI (SAS), PCI-Express (PCIe) 3. 62 (or later), logical drives may become inaccessible. 5. Search the support knowledge base, download drivers and patches, create and manage cases, and learn from expert users in forums. Here's my experience with very similar equipment (tested on two separate servers), different O/S, in the hope it might be useful. Everything I wrote here continues to be true: Third-party SSD solutions in ProLiant Gen8 servers. HPE Technology Service Portfolio. HPE Smart Array P440ar Controller cabling; HPE Smart Array P840ar Controller cabling; Universal media bay cabling; 150W PCIe power cable option; M. vib for P440ar? Solved: When I goto:. VMWare is ESXi 6. Looking back through discussions re- Dell H730, it seems that way back, consensus was that putting the H730 into HBA mode "wasn't really" the same as having a JBOD HBA and "bad things" would happen if you did. . Siga estos pasos para intentar resolver: 1 - Conecte el disco en el servidor Gen9 y reinicie el servidor; 2 - Presione F10 para acceder a Intelligent Provisioning; 3 - Seleccione la opción "Perform Maintenance"; 4 - Seleccione la opción Smart Storage Administrator SSA; 5 - Seleccione la Smart Array P440ar; 6 - Haga clic en el botón. HPE Smart Array P840ar Controller cabling. 12LFF drives at the front, and 3LFF drives. Feb 15, 2018. • 4LFF drive configuration — Connect the 4LFF. 0 Custom Image, download the ISO from VMware downloads and install. HP Proliant Smart Array P440ar is showing alarm. 52-6. Welcome to Software and Drivers for . 26. exe) The. The firmware blocks the following operations if reconstruction is in progress: Any descriptor command (DCMD) related to configuration changes. Version History: RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. 7 i386 on the newest HP DL380 GEN9 server with P440ar storage array. 20 Last Recommended or Critical Version: 7. 0 U3 (latest in compatibility list) - we did not reach this point yet. There is any software to mesure the IOs? Thanks. It looks like the errors / timeouts on newer ms-be machines might be due to a missing firmware upgrade for the hardware raid controller P840. I'd ensure your SmartArray firmware is current as can be, it had some problems through the 4. 1 The HP Dynamic Smart Array B110i/B120i/B320i controller driver for Ubuntu 12. Flashing RAID Firmware. Expands storage capacity in an array or change RAID levels. This item: HP Smart Array P440ar/2GB with FBWC Storage Controller Plug-in Card (726736-B21) $181. Downloaded the latest drivers from HP, but when I looked in the Device Manager, the HP P440ar controller was active without errors. The HPE 726736-B21 Smart Array P440ar Controller is a Flexible Smart Array, 12 Gb/s SAS RAID controller that provides enterprise-class storage performance, increased internal scalability with SAS Expander Card, and data protection for HPE ProLiant Gen9 rack and tower servers. 00How to swicth HP proliant Gen8 P420i smart array controller to hda - mode. And every 8 hdd's connected is green/ok. 4. H244br, P240nr, P244br, P246br, P440ar, P440, P441, P542D, P741m, P840, P840ar, and P841. Try installing driver hpsa version 6. 52. Benefits Update the server firmware ("Methods for updating the firmware" on page 12). Firmware Version : 4. HPE SSACLI – License key. 4 Ghz - HP SmartArray P440ar (firmware version 7. Boot up the server and acknowledge errors about failed drives.